Search in Category

SCBA (Self Contained Breathing Apparatus)

Search Filters

  • AIR SYSTEMS INTERNATIONAL x

Filter Your Search

SCBA (Self Contained Breathing Apparatus)

Respiratory Protection » SCBA (Self Contained Breathing Apparatus) 
Viewing Page 1 of 12 (142 results)
100 CFM AUTO-AIR BOX ON 23 SERIES CART

100 CFM AUTO-AIR BOX ON 23 SERIES CART

Items #: AIR BB100-23AA

Operates with 2400 - 5000 PSI cylinders. Features 100 cfm Electric Auto-Air Large Cart - (123 cfm flow capacity) Requires 115 Volts AC 4 couplings Please specify 1/4” Hansen style or Schrader style fittings when ordering Other fittings available for an additional charge Holds two 87 CF air cylinders 2 year warranty on sensor and monitor Applications Confined space entry Hazardous material handling Boiler cleaning operations Nuclear work Fuel cell maintenance Tank entry and cleaning
Call For Availability
UOM : EA
$5,895.00

100 CFM INTRINSICALLY SAFE AUTO-AIR

Items #: AIR BB100COAAP

Pneumatic system features a reserve air trigger at 60 psig and / or loss of electrical power, it automatically switches to reserve air cylinder (or cylinders). Local & optional remote alarms will signal workers that their primary air system is in failure & has switched to a back up air supply system. If IDLH work environments exist, the Auto-Air Breather Box option should be considered. The Auto-Air filtration system was developed to provide Grade-D breathing air with full automatic reserve air in the event of either electrical failure or reduced pressure from the main air source while working in hazardous environments. Reserve air activation occurs at 60 psi and/or loss of electrical supply, the system automatically switches to the reserve air cylinder(s). Local and optional remote alarms signal the workers that the primary air system has failed and has switched to the back-up air system Features Intrinsically safe CSA certified Auto-Air Breather Box CO monitor has a flow capacity of 100 CFM with 4 couplings CSA approved Class I, Div. 1, groups D and C Filtration efficiency 99.99 percent @ 0.01 micron Fully Automatic Reserve Air System for Work in IDLH Environments Note: IDLH conditions require the use of a pressure demand respirator with at least a 5 minute escape cylinder The primary air line connection is attached from the compressor to the Auto-Air Breather Box A reserve air line is attached from a single or bank of air cylinders based on the required egress duration and number of workers using the system The system can be tested prior to each use to ensure proper function of the Auto-Air system Always size the reserve air systems to allow an adequate safety factor for all workers to egress the environment Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
Call For Availability
UOM : EA
$3,795.00
AUTO-AIR  CART 100 CFM

AUTO-AIR CART 100 CFM

Items #: AIR BB100HTAA

Operates with 2400 - 5000 PSI cylinders. Features 100 cfm Electric Auto-Air Small Cart - (123 cfm flow capacity) Requires 115 Volts AC 4 couplings Please specify 1/4” Hansen style or Schrader style fittings when ordering Other fittings available for an additional charge Holds two 60 CF air cylinders 2 year warranty on sensor and monitor Applications Confined space entry Hazardous material handling Boiler cleaning operations Nuclear work Fuel cell maintenance Tank entry and cleaning
Call For Availability
UOM : EA
$6,195.00

" AUTO-AIR CART, 100 CFM - NO CYLINDERS

Items #: AIR BB100HTAAP

Operates with 2400 - 5000 PSI cylinders and is suitable for hazardous locations. Intrinsically Safe (IS) CO Monitors are CSA Approved for Class I, Division 1, Groups C and D Environments. Units are DC 9-Volt Operation Only Features 100 cfm Intrinsically Safe Auto-Air Cart Small - (123 cfm flow capacity) 4 couplings Please specify 1/4” Hansen style or Schrader style fittings when ordering Other fittings available for an additional charge Holds two 60 CF air cylinders 2 year warranty on sensor and monitor Applications Refineries Chemical and Pharmaceutical manufacturing Refueling applications Tank cleaning Decon required situations Grain silo entry All lights and remote alarms are pneumatically operated and spark free. The intrinsically safe CO monitor is CSA approved and operates on 9-volt DC batteries only.
Call For Availability
UOM : EA
$6,195.00

15 CFM FILTRATION PANEL - 1 FITTING

Items #: AIR BB15COPMIS

The system filters compressor air to provide respirator users with Grade-D quality air. The first stage element filters bulk water and particulate, the second stage coalescing filter removes atomized oils and ultra-fine particulate, and the third stage removes organic vapors and odors. Filter change indicators are standard on all three filtration stages. Filtration efficiency is 99.99% @ .01 microns. A built-in intrinsically safe carbon monoxide monitor operates on 9-volt DC for continuous detection. A high intensity audible alarm and light signals the workers of high CO content in their breathing air. A 115 VAC electrical conduit box is provided as standard to provide AC power in and connection for AC powered remote alarms. Filtration components are mounted on powder coated steel panel. Features 15 CFM (30 CFM flow capacity) CSA Approved intrinsically safe CO carbon monoxide monitor 99.99 percent filtration efficiency @ .01 microns 1 couplings or NPT outlet Integrated carbon monoxide (CO) monitor uses 9 Volts DC for continuous detection Audible high intensity alarm & light will signal workers to high CO in breathing air supply All portable and fixed breathing air filtration systems meet or exceed OSHA 1910.134, Canadian Z180.1 Breathing Air Standards and British Standard BS-EN 12021:1999 “RESPIRATORY PROTECTIVE DEVICES” All filtration units are designed to flow the NIOSH maximum capacity per worker Air Systems provides at NO CHARGE your first lab certified air quality test of your new breathing air filtration device Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge.
Call For Availability
UOM : EA
$1,595.00
50 CFM  AUTO-AIR  BREATHER BOX

50 CFM AUTO-AIR BREATHER BOX

Items #: AIR BB50-COAA

Standard electric system features a reserve air trigger at 60 psig and / or loss of electrical power, it automatically switches to reserve air cylinder (or cylinders). Local & optional remote alarms will signal workers that their primary air system is in failure & has switched to a back up air supply system. If IDLH work environments exist, the Auto-Air Breather Box option should be considered. The Auto-Air filtration system was developed to provide Grade-D breathing air with full automatic reserve air in the event of either electrical failure or reduced pressure from the main air source while working in hazardous environments. Reserve air activation occurs at 60 psi and/or loss of electrical supply, the system automatically switches to the reserve air cylinder(s). Local and optional remote alarms signal the workers that the primary air system has failed and has switched to the back-up air system Features 50 cfm Auto-Air Breather Box - (79 cfm flow capacity) - 4 couplings Filtration efficiency 99.99 percent @ 0.01 micron Fully Automatic Reserve Air System for Work in IDLH Environments Note: IDLH conditions require the use of a pressure demand respirator with at least a 5 minute escape cylinder The primary air line connection is attached from the compressor to the Auto-Air Breather Box A reserve air line is attached from a single or bank of air cylinders based on the required egress duration and number of workers using the system The system can be tested prior to each use to ensure proper function of the Auto-Air system Always size the reserve air systems to allow an adequate safety factor for all workers to egress the environment Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
Call For Availability
UOM : EA
$2,795.00
50 CFM BREATHER BOX W/ AUTO-AIR  FEATURE

50 CFM BREATHER BOX W/ AUTO-AIR FEATURE

Items #: AIR BB50-COAAP

Pneumatic system features a reserve air trigger at 60 psig and / or loss of electrical power, it automatically switches to reserve air cylinder (or cylinders). Local & optional remote alarms will signal workers that their primary air system is in failure & has switched to a back up air supply system. If IDLH work environments exist, the Auto-Air Breather Box option should be considered. The Auto-Air filtration system was developed to provide Grade-D breathing air with full automatic reserve air in the event of either electrical failure or reduced pressure from the main air source while working in hazardous environments. Reserve air activation occurs at 60 psi and/or loss of electrical supply, the system automatically switches to the reserve air cylinder(s). Local and optional remote alarms signal the workers that the primary air system has failed and has switched to the back-up air system Features 50 cfm Intrinsically Safe Auto-Air TM Breather BoxTM (79 cfm flow capacity) - 4 couplings CSA approved Class I, Div. 1, groups D and C Filtration efficiency 99.99 percent @ 0.01 micron Fully Automatic Reserve Air System for Work in IDLH Environments Note: IDLH conditions require the use of a pressure demand respirator with at least a 5 minute escape cylinder The primary air line connection is attached from the compressor to the Auto-Air Breather Box A reserve air line is attached from a single or bank of air cylinders based on the required egress duration and number of workers using the system The system can be tested prior to each use to ensure proper function of the Auto-Air system Always size the reserve air systems to allow an adequate safety factor for all workers to egress the environment Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
Call For Availability
UOM : EA
$3,095.00
50 CFM INTRINSICALLY SAFE BREATHER BOX

50 CFM INTRINSICALLY SAFE BREATHER BOX

Items #: AIR BB50-COIS

The 1st stage element will filter bulk water & particulates, the 2nd stage coalescing filter will remove atomized oils & ultra-fine particulates & the 3rd stage will remove sorganic vapors & odors. A standard airline monitor operates with 9 Volt batteries & an audible alarm warns workers to high carbon monoxide concentrations. Features Intrinsically safe Flow capacity 79 CFM Filtration efficiency of 99.99 percent @ 0.01 micron (Optional) Point of attachment boxes can extend respiratory usage to over 300 ft. 1/4 inch hansen or schrader type fittings Engineered to be used in closed & upright positions to prevent internal contamination 9 Volt batteries, 8 - 16 Volts DC or 115 Volts AC for continuous air monitoring External audible alarm & light OSHA 1910.134 compliant Canadian Z180.1 BS-EN 12021:1999
Call For Availability
UOM : EA
$1,995.00

FILTER REPLACEMNTCHARCOAL

Items #: AIR BB50-D

Air Systems International Breather Box™ 50 CFM Stage 3 Replacement Charcoal Filter is used to remove organic vapors and objectionable odors.
Call For Availability
UOM : EA
$65.00
AUTO-AIR  CART 50 CFM

AUTO-AIR CART 50 CFM

Items #: AIR BB50-HTAA

Operates with 2400 - 5000 PSI cylinders. Features 50 cfm Electric Auto-Air Small Cart - (79 cfm flow capacity) Requires 115 Volts AC 4 couplings Please specify 1/4” Hansen style or Schrader style fittings when ordering Other fittings available for an additional charge Holds two 60 CF air cylinders 2 year warranty on sensor and monitor Applications Confined space entry Hazardous material handling Boiler cleaning operations Nuclear work Fuel cell maintenance Tank entry and cleaning
Call For Availability
UOM : EA
$4,995.00
75 CFM FILTRATION PANEL W/CO MONITOR

75 CFM FILTRATION PANEL W/CO MONITOR

Items #: AIR BB75-COPM

The system filters compressor air to provide respirator users with Grade-D quality air. The first stage element filters bulk water and particulate, the second stage coalescing filter removes atomized oils and ultra-fine particulate, and the third stage removes organic vapors and odors. Filter change indicators are standard on all three filtration stages. Filtration efficiency is 99.99% @ .01 microns. A built-in carbon monoxide monitor operates on 115 VAC, or 8-16 VDC for continuous detection. A high intensity audible alarm and light signals the workers of high CO content in their breathing air. A 115 VAC electrical conduit box is provided as standard to provide AC power in and connection for AC powered remote alarms. Filtration components are mounted on powder coated steel panel. Features 75 CFM (97 CFM flow capacity) CO carbon monoxide monitor 99.99 percent filtration efficiency @ .01 microns 6 couplings or NPT outlet Integrated carbon monoxide (CO) monitor uses 115 Volts AC or 8 to 16 Volts DC for continuous detection Audible high intensity alarm & light will signal workers to high CO in breathing air supply All portable and fixed breathing air filtration systems meet or exceed OSHA 1910.134, Canadian Z180.1 Breathing Air Standards and British Standard BS-EN 12021:1999 “RESPIRATORY PROTECTIVE DEVICES” All filtration units are designed to flow the NIOSH maximum capacity per worker Air Systems provides at NO CHARGE your first lab certified air quality test of your new breathing air filtration device Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge.
Call For Availability
UOM : EA
$2,295.00
CALIBRATION GAS-10 PPM CO/AIR- 103 LITER

CALIBRATION GAS-10 PPM CO/AIR- 103 LITER

Items #: AIR BBG-10103

CALIBRATION GAS-10 PPM CO/AIR- 103 LITER WARNING: This product can expose you to chemicals including Carbon Monoxide, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information, visit www.P65Warnings.ca.gov
Call For Availability
UOM : EA
$180.00
View Page:   1 2 3 4 5 6 7 8 9 10 11 NEXT »