Search in Category

SCBA (Self Contained Breathing Apparatus)

Search Filters

  • Air Systems International x

Filter Your Search

SCBA (Self Contained Breathing Apparatus)

Respiratory Protection » SCBA (Self Contained Breathing Apparatus) 
Viewing Page 1 of 14 (167 results)
"TWIN-AIR COMPRESSOR,3-PERSON, 110PSI"

"TWIN-AIR COMPRESSOR,3-PERSON, 110PSI"

Items #: AIR TA-3

Compressor system consists of a receiver tank / mounting frame which provides cooled air to within 10 degress of the ambient temperature which is perfect for pressure demand respirator systems. It also provides pressure which ranges to 110 PSIG & has an integrated skid plate for easy stair climbing. Features 2 HP electric motor - 1750 RPM Rotary vane type air compressor 110 PSI out 2 HP electric motor 3-worker operation - pressure demand respirators only 1750RPM continuous duty & thermally protected Low maintenance with 500 hrs between oil change 10 inch pneumatic tires 50,000 hr min vane life Food grade USDA approved oil in compression end Automatic pressure unloading with full modulation air control Requires Breather Box Grade-D filtration package Noise level under 70 dbA @ 3 Ft. 8 Gallon Twin Air tank assembly, 8.5 CF air storage at 110 PSI ASME coded 1/2 inch 5000 series Hansen coupling air outlet (Optional) explosion proof motor - 230 / 3 VAC only - Model TA-3EXP Size (L x W x H) 46 x 24 x 22 inches Weight 150 pounds
Usually Ships 2-5 Days
UOM : EA
$3,846.50
4-POSITION AIR CYLINDER RACK

4-POSITION AIR CYLINDER RACK

Items #: AIR TR-4

4-POSITION AIR CYLINDER RACK HOLDS SCBA OR SCUBA CYLINDERS
Usually Ships 2-5 Days
UOM : EA
$112.00
11-CYLINDER SCBA RACK - ALUMINUM - 48 H

11-CYLINDER SCBA RACK - ALUMINUM - 48 H

Items #: AIR AK24-11

The AIR-KADDY's innovative modular aluminum design allows for expansion to accommodate your SCBA storage requirements today and in the future! This free standing SCBA storage rack is lined with nylon pads to prevent cylinder scratches. Series 24 is designed to fit in fire/rescue trailers and trucks requiring a narrower profile. Features 11 breathing air cylinder storage capacity Custom sizes available Optional thread savers available Size (W x D x H) - 25.25 x 22.25 x 48 inches
Usually Ships 2-5 Days
UOM : EA
$2,062.50
8-CYLINDER SCBA RACK - ALUMINUM - 32 H

8-CYLINDER SCBA RACK - ALUMINUM - 32 H

Items #: AIR AK24-8

The AIR-KADDY's innovative modular aluminum design allows for expansion to accommodate your SCBA storage requirements today and in the future! This free standing SCBA storage rack is lined with nylon pads to prevent cylinder scratches. Series 24 is designed to fit in fire/rescue trailers and trucks requiring a narrower profile. Features 8 breathing air cylinder storage capacity Custom sizes available Optional thread savers available Size (W x D x H) - 25.25 x 22.25 x 32 inches
Usually Ships 2-5 Days
UOM : EA
$1,687.50
FIXED BREATHING AIR PANELS-EXPLOSION

FIXED BREATHING AIR PANELS-EXPLOSION

Items #: AIR B50-COPMEX

The viewing window is mounted onto a steel panel. The 50-EXALPST explosion-proof visual alarm and strobe is designed for use with the explosion-proof panel and has a high intensity pneumatic audible alarm with adjustable volume. Contact Us for additional details. Air Systems' engineering and design team will manufacture a custom Grade-D breathing air system to meet your most stringent needs.
Usually Ships 2-5 Days
UOM : EA
$5,596.50
Stage 2 Coalescing Filter, 100-175 CFM

Stage 2 Coalescing Filter, 100-175 CFM

Items #: AIR BB100-C
Brand: Air Systems International

Air Systems International Replacement Coalescing Filter has O-ring construction and fits 100 - 175 CFM series.
Usually Ships 2-5 Days
UOM : EA
$108.50
Breather Box, 100 cfm, 4 Couplings

Breather Box, 100 cfm, 4 Couplings

Items #: AIR BB100-CO
Brand: Air Systems International

The Breather Box is a portable Grade-D filtration system designed to provide breathing air for a specific number of workers. The system filters incoming air from a compressor to provide respirator users with Grade-D quality air and monitors for CO. The 1st stage element will filter bulk water & particulates, the 2nd stage coalescing filter will remove atomized oils & ultra-fine particulates & the 3rd stage will remove sorganic vapors & odors. The standard carbon monoxide (CO) airline monitor operates on disposable 9-volt batteries, 8-16 volt DC, or 115 VAC for continuous air monitoring. An external audible alarm and light signals the workers of high CO content. A remote alarm jack is provided. Features (Optional) Point of attachment boxes can extend respiratory usage to over 300 ft. Filtration efficiency 99.99 percent @ 0.01 micron 1/4 inch hansen or schrader type fittings Engineered to be used in closed & upright positions to prevent internal contamination 8 - 16 Volts DC or 115 Volts AC for continuous air monitoring External audible alarm & light OSHA 1910.134 compliant Size (L x H x D) - 26.5 X 21 X 9 inches
Usually Ships 2-5 Days
UOM : EA
$1,746.50
100 CFM  AUTO-AIR  BREATHER BOX

100 CFM AUTO-AIR BREATHER BOX

Items #: AIR BB100-COAA

Standard electric system features a reserve air trigger at 60 psig and / or loss of electrical power, it automatically switches to reserve air cylinder (or cylinders). Local & optional remote alarms will signal workers that their primary air system is in failure & has switched to a back up air supply system. If IDLH work environments exist, the Auto-Air Breather Box option should be considered. The Auto-Air filtration system was developed to provide Grade-D breathing air with full automatic reserve air in the event of either electrical failure or reduced pressure from the main air source while working in hazardous environments. Reserve air activation occurs at 60 psi and/or loss of electrical supply, the system automatically switches to the reserve air cylinder(s). Local and optional remote alarms signal the workers that the primary air system has failed and has switched to the back-up air system Features 100 cfm Auto-Air Breather Box - (123 cfm flow capacity) - 4 couplings Filtration efficiency 99.99 percent @ 0.01 micron Fully Automatic Reserve Air System for Work in IDLH Environments Note: IDLH conditions require the use of a pressure demand respirator with at least a 5 minute escape cylinder The primary air line connection is attached from the compressor to the Auto-Air Breather Box A reserve air line is attached from a single or bank of air cylinders based on the required egress duration and number of workers using the system The system can be tested prior to each use to ensure proper function of the Auto-Air system Always size the reserve air systems to allow an adequate safety factor for all workers to egress the environment Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
Usually Ships 2-5 Days
UOM : EA
$2,656.50
BB100-CO PANEL MOUNT - 4 FITTINGS

BB100-CO PANEL MOUNT - 4 FITTINGS

Items #: AIR BB100-COPM

The system filters compressor air to provide respirator users with Grade-D quality air. The first stage element filters bulk water and particulate, the second stage coalescing filter removes atomized oils and ultra-fine particulate, and the third stage removes organic vapors and odors. Filter change indicators are standard on all three filtration stages. Filtration efficiency is 99.99% @ .01 microns. A built-in carbon monoxide monitor operates on 115 VAC, or 8-16 VDC for continuous detection. A high intensity audible alarm and light signals the workers of high CO content in their breathing air. A 115 VAC electrical conduit box is provided as standard to provide AC power in and connection for AC powered remote alarms. Filtration components are mounted on powder coated steel panel. Features 100 CFM (123 CFM flow capacity) CO carbon monoxide monitor 99.99 percent filtration efficiency @ .01 microns 4 couplings or NPT outlet Integrated carbon monoxide (CO) monitor uses 115 Volts AC or 8 to 16 Volts DC for continuous detection Audible high intensity alarm & light will signal workers to high CO in breathing air supply All portable and fixed breathing air filtration systems meet or exceed OSHA 1910.134, Canadian Z180.1 Breathing Air Standards and British Standard BS-EN 12021:1999 “RESPIRATORY PROTECTIVE DEVICES” All filtration units are designed to flow the NIOSH maximum capacity per worker Air Systems provides at NO CHARGE your first lab certified air quality test of your new breathing air filtration device Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge.
Usually Ships 2-5 Days
UOM : EA
$1,816.50
BB100-CO/O2 PANEL MOUNT - 4 FITTINGS

BB100-CO/O2 PANEL MOUNT - 4 FITTINGS

Items #: AIR BB100CO2PM

The system filters compressor air to provide respirator users with Grade-D quality air. The first stage element filters bulk water and particulate, the second stage coalescing filter removes atomized oils and ultra-fine particulate, and the third stage removes organic vapors and odors. Filter change indicators are standard on all three filtration stages. Filtration efficiency is 99.99% @ .01 microns. A built-in intrinsically safe carbon monoxide monitor operates on 115 VAC, or 8-16 VDC for continuous detection. A high intensity audible alarm and light signals the workers of high CO content in their breathing air. A 115 VAC electrical conduit box is provided as standard to provide AC power in and connection for AC powered remote alarms. Filtration components are mounted on powder coated steel panel. Features 100 CFM (123 CFM flow capacity) O2 oxygen & CO carbon monoxide monitor 99.99 percent filtration efficiency @ .01 microns 4 couplings or NPT outlet Integrated carbon monoxide (CO) monitor uses 115 Volts AC or 8 to 16 Volts DC for continuous detection Audible high intensity alarm & light will signal workers to high CO in breathing air supply All portable and fixed breathing air filtration systems meet or exceed OSHA 1910.134, Canadian Z180.1 Breathing Air Standards and British Standard BS-EN 12021:1999 “RESPIRATORY PROTECTIVE DEVICES” All filtration units are designed to flow the NIOSH maximum capacity per worker Air Systems provides at NO CHARGE your first lab certified air quality test of your new breathing air filtration device Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge.
Usually Ships 2-5 Days
UOM : EA
$2,166.50

100 CFM INTRINSICALLY SAFE AUTO-AIR

Items #: AIR BB100COAAP

Pneumatic system features a reserve air trigger at 60 psig and / or loss of electrical power, it automatically switches to reserve air cylinder (or cylinders). Local & optional remote alarms will signal workers that their primary air system is in failure & has switched to a back up air supply system. If IDLH work environments exist, the Auto-Air Breather Box option should be considered. The Auto-Air filtration system was developed to provide Grade-D breathing air with full automatic reserve air in the event of either electrical failure or reduced pressure from the main air source while working in hazardous environments. Reserve air activation occurs at 60 psi and/or loss of electrical supply, the system automatically switches to the reserve air cylinder(s). Local and optional remote alarms signal the workers that the primary air system has failed and has switched to the back-up air system Features Intrinsically safe CSA certified Auto-Air Breather Box CO monitor has a flow capacity of 100 CFM with 4 couplings CSA approved Class I, Div. 1, groups D and C Filtration efficiency 99.99 percent @ 0.01 micron Fully Automatic Reserve Air System for Work in IDLH Environments Note: IDLH conditions require the use of a pressure demand respirator with at least a 5 minute escape cylinder The primary air line connection is attached from the compressor to the Auto-Air Breather Box A reserve air line is attached from a single or bank of air cylinders based on the required egress duration and number of workers using the system The system can be tested prior to each use to ensure proper function of the Auto-Air system Always size the reserve air systems to allow an adequate safety factor for all workers to egress the environment Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
Usually Ships 2-5 Days
UOM : EA
$2,656.50
Breather Box, 15 cfm, 1 Coupling

Breather Box, 15 cfm, 1 Coupling

Items #: AIR BB15-CO
Brand: Air Systems International

It also has standard filter change indicators for for all 3 filtration stages. The Breather Box is a portable Grade-D filtration system designed to provide breathing air for a specific number of workers. The system filters incoming air from a compressor to provide respirator users with Grade-D quality air and monitors for CO. The first stage element filters bulk water and particulate and has an auto drain. The second stage coalescing filter eliminates atomized oils, mists, ultra-fine particulates, and has an auto drain. The third stage filter removes organic vapors and odors and has a manual drain. Filter change indicators are standard on all three stages of filtration. Filtration efficiency is 99.99% @ .01 micron. All Breather Boxes are designed to be used in the upright and closed position to prevent internal contamination. The standard carbon monoxide (CO) airline monitor operates on 8-16 volt DC, or 115 VAC for continuous air monitoring. An external audible alarm and light signals the workers of high CO content. Point-of-Attachment (POA) boxes can extend respirator usage beyond 300 feet. Features CO monitoring 15 cfm Breather Box - (30 cfm flow capacity) 1 coupling 99.99 percent filtration efficiency @ .01 micron External light & alarm signals Remote alarm jack Canadian Z180.1 BS-EN 12021:1999 OSHA 1910.134 Please specify 1/4” Hansen style or Schrader style fittings when ordering. Other fittings available for an additional charge
Usually Ships 2-5 Days
UOM : EA
$1,046.50
View Page:   1 2 3 4 5 6 7 8 9 10 11 NEXT »