G8 Portable Gas Detector
G8 Portable Gas Detector
Portable Multi-Gas Detector
Key Features:
- Detect Up to 5 Gases
- Advanced 4G LTE Cellular Connectivity
- Swappable Cartridges
- Sensor Readings
- Configurable Alert Thresholds
Ideal For:
- Fire & Rescue
- CBRNe & HazMat
- State & Local Operations
- Federal Government
- Military
Get more information or request a quote on Blackline Safety solutions from Safeware.
- Description
- Features
- Specifications
- Pre-Made Sensor Packages
- Sensor Options
- Downloads
When hazardous gases are present, there’s no room for uncertainty.
G8 delivers advanced gas detection in a rugged, intrinsically safe device designed to perform in the most demanding environments.
With swappable cartridges and coverage for virtually any gas your team may encounter, G8 provides reliable protection without slowing work down.
And it does so much more than detect gases.
G8 combines real-time alerts, built-in radio communication, and direct-to-cloud data to keep workers safe while improving visibility, response, and productivity across every site.
Features and Benefits
- Detect up to 5 gases simultaneously from 20+ sensors, with optional pump to easily switch between pre-entry and continuous monitoring.
- Advanced 4G LTE cellular connectivity with auto-switching between major carriers for the best coverage.
- Swappable cartridges to adapt to any situation (lone worker, single-gas, multi-gas, or multi-gas pump).
- Sensor readings to monitor the latest gas data, spot elevated readings sooner and act faster.
- Configurable alert thresholds to align with site policies, regulatory requirements, and job-specific risk profiles.
- Field-optimized, industrial design with a bright display and quick-access flashlight for demanding work environments.
- Dual-band GPS/GNSS to pinpoint worker location, ensure quick incident response, and to show when and where every alarm, event and near-miss takes place.
- Real-time alerts for time-weighted average (TWA), short-term exposure limit (STEL), high/low gas levels, bump tests, calibrations, falls, no-motion, missed check-ins, proximity-based events, and silent and emergency SOS.
- Direct-to-cloud data streaming from the field to Blackline Live for alert management and worksite visibility.
- 24/7 live monitoring through your own safety control center, Blackline’s in-house Safety Operations Center (SOC), or our global Alarm Receiving Center (ARC) partners.
- Emergency Voice with a real person checking in when an alert is triggered and sending immediate help if needed.
- Push-to-Talk works just like a two-way radio, using a dedicated button for clear audio and optional remote speaker mic (RSM) rivaling any industrial radio — so teams can coordinate quickly across sites.
- Text messaging for fast mass notifications, like evacuations or extreme weather events, and for workers to send custom or pre-set messages to monitoring personnel when help is needed.
- Automated reporting that saves you time, shows if safety devices are being worn, turned on, and calibrated for easier compliance management.
- Historical trend data on gas leaks and exposures supports incident investigation, root cause analysis, and continuous improvement of gas safety practices.
- ZoneAware™ to draw site-specific areas and understand who is in each zone, spot bottlenecks, and monitor movement to muster points.
| Device Specifications | |
|---|---|
| Material | Polycarbonate over molded with a static dissipative thermoplastic elastomer (TPE) |
| Size & Weight |
G8 with Standard Cartridge Size: 122 mm x 65 mm x 42 mm (4.8” x 2.56” x 1.65”) Weight: 207 g (7.30 oz) G8 with Single-gas Cartridge G8 with Multi-gas Diffusion Cartridge G8 with Multi-gas Pumped Cartridge |
| Temperature |
Storage temperature: -30°C to 60°C (-22°F to 140°F)
Operating temperature: -20°C to 55°C (-4°F to 131°F) Charging temperature: 0°C to 40°C (32°F to 104°F) |
| Humidity | 15-90% RH Non-condensing |
| Data | The default location schedule on G8 is every five minutes. Location and sensor readings are recorded every 10 seconds if either of the following is true: • “10-second locations and gas data” is enabled • Any sensor is reading above the extended blanking range |
| Approvals/Standards |
Canada and USA: Class I Division 1 Group A,B,C,D T4; Class I Zone 0 AEx ia IIC T4; Ex ia IIC T4 Ga
LEL Performance: CSA C22.2 No.152; ISA 12.13.01; 60079-29-1 CE/RoHS IECEx: Ex ia IIC T4 Ga ATEX: Ex ia IIC T4 Ga |
| IP Rating | IP67 certified |
| Sound Levels | Speaker sound pressure level: ~95 dB @ 30 cm (~95 dB @ 11.8”) |
| Sensors | Cartridge selection supports up to 4 sensors, and up to 5 gases |
| Warranty |
Purchase: 2 years on base, cartridge, and sensors, with the option to extend to up to 5 years
Blend: 2 years on base; cartridge and sensors for the entire term Lease: Entire lease term |
| Connectivity | |
|---|---|
| Location Awareness |
Multi-constellation Support (GPS, Galileo, GLONASS, QZSS, BeiDou) Dual-band (L1 and L5) GNSS receiver Assisted GNSS: Yes |
| Cellular |
EU/AZ Variant: 4G LTE bands: 12,13,18,19,20,26,5,8,28,2,3,1,4,7,38,39,40,41 3G UMTS bands: 5,8,1,2 2G GSM bands: 5,8,3,2 NA Variant: |
| Bluetooth | Complies with Bluetooth® Core Specification version 4.2 including BR/EDR/Bluetooth® LE |
| NFC | Tag Reading 13.56 MHz |
| Wireless Updates |
Over-the-air device configurations Over-the-air firmware upgrades |
| Battery and Charging | |
|---|---|
| Rechargeable Battery | Li-ion battery: 1350 mAh |
| Charge Time | 4 hours |
| Battery Life | Battery life in diffusion mode: 18 hours at 20°C (68°F) with LEL-(IR or MPS), H2S, CO, and O2 cartridge under normal connectivity conditions |
| Display and Controls | |
|---|---|
| Display | 2.13”, 240 x 320 pixel graphical, high contrast, 64-bit color liquid crystal display with front lighting |
| Buttons |
Menu system: Driven by three-button keypad and side up/down keys
Push-to-Talk (PTT): For two-way radio communication Flashlight: For fast flashlight access |
| Flashlight | 5000K CCT, 35 lumens |
| SOS Latch | Send emergency SOS alert |
| Languages | Multi-language support: EN, FR, ES, DE, IT, NL, PT |
G8 Portable Gas Detector (LEL-MPS, H2S, CO, O2) w/ 5 Year Warranty
G8C Purchase Model, Cellular (4G/LTE), Standard (Telenor) SIM, North America, 5-Year Warranty, Multi-Gas Pumped Cartridge, LEL-MPS Sensor, H2S Sensor, CO Sensor, O2 Sensor, Standard Service Plan, No Third Party Monitoring, No Voice, No PTT, No Team Calling, 5-Years
Part Number: BLS J-G8C-01-NA2-P-FHMO-5Y-SXXXX-5Y
5 Year Warranty
| Gas | Sensor Type | Range | Resolution |
|---|---|---|---|
| LEL – Molecular Property Spectrometer (LEL-MPS)3 | MPS | 0-100% LEL | 1% LEL |
| Hydrogen Sulfide (H2S) | Electrochemical | 0-100 ppm | 0.1 ppm |
| Carbon Monoxide (CO) | Electrochemical | 0–500 ppm | 1 ppm |
| Oxygen (O2) | Pumped Electrochemical | 0-25% vol | 0.1% vol |
G8 Portable Gas Detector (LEL-MPS, PID, COSH, O2)
G8C Purchase Model, Cellular (4G/LTE), Standard (Telenor) SIM, North America, 5-Years Warranty, Multi-Gas Pumped Cartridge, LEL-MPS Sensor, CO/H2S Sensor, PID Sensor, O2 Sensor, Standard Service Plan, No Third Party Monitoring, No Voice, No PTT, No Team Calling, 5-Years
Part Number: BLS J-G8C-01-NA2-P-DFOV-5Y-SXXXX-5Y
5 Year Warranty
| Gas | Sensor Type | Range | Resolution |
|---|---|---|---|
| LEL – Molecular Property Spectrometer (LEL-MPS)3 | MPS | 0-100% LEL | 1% LEL |
| Photoionization (PID) | PID | 0-4,000 ppm | Dynamic Resolution2, 0.1 ppm |
| COSH (CO & H2S) | Electrochemical | 0–500 ppm CO and 0–100 ppm H2S | 1 ppm CO and 0.1 ppm H2S |
| Oxygen (O2) | Pumped Electrochemical | 0-25% vol | 0.1% vol |
| Gas | Sensor Type | Range | Resolution |
|---|---|---|---|
| Ammonia (NH3) | Electrochemical | 0-100 ppm | 0.1 ppm |
| High Range Ammonia (NH3) | Electrochemical | 0-500 ppm | 1 ppm |
| Carbon Dioxide (CO2) | NDIR | 0-50,000 ppm | 50 ppm |
| Carbon Monoxide (CO) | Electrochemical | 0–500 ppm | 1 ppm |
| Chlorine (CL2) | Electrochemical | 0–20 ppm | 0.1 ppm |
| Chlorine Dioxide (CLO2) | Electrochemical | 0–2 ppm | 0.1 ppm |
| LEL-infrared (LEL-IR) | NDIR | 0–100% LEL | 1% LEL |
| LEL Molecular Property Spectrometer (LEL-MPS)3 | MPS | 0–100% LEL | 1% LEL |
| COSH (CO & H2S) | Electrochemical | 0–500 ppm CO and 0–100 ppm H2S | 1 ppm CO and 0.1 ppm H2S |
| High Range Carbon Monoxide (CO) | Electrochemical | 0–2000 ppm | 5 ppm |
| High Range Hydrogen Sulfide (H2S) | Electrochemical | 0-500 ppm | 0.5 ppm |
| Hydrogen Cyanide (HCN) | Electrochemical | 0–30 ppm | 0.1 ppm |
| Hydrogen Fluoride (HF)1 | Electrochemical | 0-10 ppm | 0.1 ppm |
| Hydrogen Resistant Carbon Monoxide (CO-H) | Electrochemical | 0-500 ppm | 1 ppm |
| Hydrogen Sulfide (H2S) | Electrochemical | 0-100 ppm | 0.1 ppm |
| Nitrogen Dioxide (NO2) | Electrochemical | 0-50 ppm | 0.1 ppm |
| Oxygen (O2) | Pumped Electrochemical | 0-25% vol | 0.1% vol |
| Ozone (O3)4 | Electrochemical | 0.1 ppm | 0.1 ppm |
| Photoionization (PID) | PID | 0-4,000 ppm | Dynamic Resolution2, 0.1 ppm |
| Sulfur Dioxide (SO2) | Electrochemical | 0-100 ppm | 0.1 ppm |
| Hydrogen (H2) (Outside North America) | Electrochemical | 0-40,000 ppm | 1%LEL (400 ppm H2) |